SPECIFICATIONS


Application: natural gas purification

Capacity: 2.5~50×104

Certification: ISO9000,ISO14000, ISO9000

Color: Customer’s Request

Configuration: stationary

OEM: Avaliable

Weight: vary

application: Natural gas dehydration

brand name: Jinxin

core components: Pressure vessel,PLC,Pump

dimension(l*w*h): Vary

key selling points: Energy saving

machinery test report: Provided

place of origin: Sichuan, China

power(w): Vary

type: Rotary Drying Equipment

video outgoing-inspection: Provided

voltage: 380v,or customized

warranty: 1 Year

weight (kg): 10000


Product features

 

 

Description:

 

The dehydration unit of feed gas is wet natural gas purification, and the unit capacity is 2.5~50×104 . The elasticity of operation is 150-100%  and the annual production time is 8000 hours.

 

The device adopts about 99.74% (wt) triethylene glycol (TEG dehydrating agent, removing the most saturated water in wet natural gas purification, purification by TEG absorber after dehydration dry gas (in the factory water dew point pressure condition < – 5 c) as a commodity to outside gas pipeline.

 

After water absorption, TEG is regenerated by the method of atmospheric pressure fire tube heating and regeneration. After heat exchange, the heat-depleted liquid is cooled and returned to the TEG absorption tower after pressurization for recycling.

 

The gas-forming components produced by the regeneration of the rich liquid are mainly water vapor and contain a small amount of hydrocarbons and gases.

 

In order to eliminate potential safety hazards and avoid direct emissions of environmental pollution, the recycled waste gas from the sulfur recovery device is discharged into the atmosphere after burning in the exhaust gas burning furnace.

 

Features:

 

1. TEG dehydration process is simple, mature technology, compared with other dehydration method can obtain a larger dew point drop. Good thermal stability. It is easy to regenerate and has the advantages of small loss, low investment and operation cost.

 

2. A lean/rich liquid heat exchanger is installed before the lean liquid circulating pump, which not only improves the operating conditions of the circulating pump, but also increases the temperature of TEG rich liquid into the triethylene glycol regenerator, effectively recovering part of the heat and reducing the consumption of fuel gas for regeneration.

 

3. Set a filter on the rich liquid channel to remove the mechanical impurities and degradation products carried in the solution system, keep the solution clean and prevent the solution from foaming, which can reduce the loss of the solvent and is conducive to the long-term stable operation of the device.

The direct fire tube heating method adopted in TEG regeneration is mature, reliable and easy to operate.

 

Technical parameters

 

 

 

 

  Inlet gas condition  
1 Flow 290.1X104 Nm3/d
2 Inlet Pressure 4.86-6.15 MPa
3 Inlet Temperature -48.98
     
  Outlet gas condition  
4 Flow 284.4X104 Nm3/d
5 Outlet pressure 4.7-5.99 MPa
6 Outlet temperature -50.29
7 H2S 20g/m3
8 CO2 3%
9 Water dew point <-5

 

 

 

Company display

 

        Perfect quality system and testing facilities                                                     Strong R & D and design capabilities

        120 R&D team provide the system solutions.                                                                      Timely delivery capability

   

       

Perfect quality system and testing facilities                                               Good after-sales service and operation technical support

  

Our projects

 

 

 

 

Company profile

 

Our cerficate

 

 

 

Visit

1234  St. #1000
San Francisco, CA
23514

Contact

[email protected]

WhatsApp 1-269-528-1612

Follow Us

Accessories
Home Office